Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer coating thickness ferrous gauges accept any ferrous probe. Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe. Scale FM7: Range: 0.

Author:Goltimuro Goramar
Country:Sweden
Language:English (Spanish)
Genre:Love
Published (Last):17 April 2007
Pages:106
PDF File Size:9.66 Mb
ePub File Size:3.34 Mb
ISBN:960-3-41906-555-3
Downloads:9599
Price:Free* [*Free Regsitration Required]
Uploader:Sarn



Each coating thickness gauge provides the user with increasing functionality - from the entry level Elcometer Model B, to the top of the range Elcometer Model T. Key features of the Elcometer Coating Thickness Gauge include:.

The importance of Coating Thickness Gauge Calibration. Formal quality systems, such as those described in ISO , require coating thickness gauges to be properly controlled, logged and calibrated.

Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.

App Store is a trademark of Apple Inc. Resolution: 0. Ideal for precision placement for the most accurate results on flat and curved surfaces. Place the probe inside the Jumbo Hand Grip and take measurements - ideal when wearing gloves.

Suitable for any Elcometer Scale 1 or Scale 2 straight probes. Ideal for precision placement for the most accurate results on medium and large diameter curved surfaces such as pipes and cylinders.

The Elcometer probe placement jig is the ideal accessory for measuring coatings on small or complex components when the highest levels of repeatability and accuracy are required. Each probe placement jig is supplied with a probe housing and a component holder to suit Scale 1 or Scale 2 straight probes.

Elcometer offers a range of individual precision foils, foil sets, coated thickness standards and zero test plates to ensure the greatest possible accuracy. Enables data to be output from the Elcometer via RS ports for the purposes of controlling automated production lines.

Simply select the Auto Repeat Mode and follow the on-screen prompts to ensure the highest level of measurement accuracy.

Click here to download the video script in English. This video features the Elcometer integral and separate models performing non-destructive coating thickness measurements on a variety of applications. This video will guide you through a range of calibration options for both the integral and the separate models. The Elcometer Dry Film Thickness Gauge can measure the thickness of a coating on smooth, and on rough or blast coated substrates; and there are a number of calibration methods for each substrate profile — including Zero, Smooth, and Rough or 2 Point.

When using the Elcometer Dry Film Thickness Gauge to measure the thickness of a coating on smooth substrates, a quick and simple method of calibrating the gauge is the Zero, or single-point calibration method. ISO simply states that if a blast profile is unknown, you should calibrate on smooth steel and then subtract a predefined correction value from the measurement taken on the coated surface.

The Elcometer Dry Film Thickness Gauge can accurately measure the thickness of a coating on smooth, and on rough or blast coated substrates. Product Description. The Elcometer Coating Thickness Gauge sets new standards; providing reliable and accurate coating thickness measurements; helping you to become more efficient.

Featuring a highly durable probe cap, the Elcometer Coating Thickness Gauge Scan Probe is a revolutionary design which allows users to take individual dry film thickness readings or rapidly scan large surface areas - without damaging the probe or the coating.

When used in conjunction with the Elcometer Coating Thickness Gauge Scan or Auto Repeat Mode, the Scan Probe enables users to significantly reduce dry film thickness inspection times without affecting accuracy. Reliable Repeatable and reproducible 2 year gauge warranty Supplied with fully traceable test certificates Batch date and time stamp facility Rugged Sealed, heavy duty and impact resistant Dust and waterproof equivalent to IP64 Scratch and solvent resistant display Durable gauge and probe construction Suitable for use in harsh environments.

In order to test the accuracy of a particular gauge it is important to have traceable coating thickness standards. Elcometer offer a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Technical Specification.

Jumbo Hand Grip Ideal for precision placement for the most accurate results on flat and curved surfaces. Data Output Controller Enables data to be output from the Elcometer via RS ports for the purposes of controlling automated production lines.

Data Sheet. How to halve inspection times using the Elcometer Scan Probe. How to measure dry film thickness using the Elcometer Coating Thickness Gauge. A range of fully interchangeable probes for the Elcometer separate coating thickness gauge. Register your product and receive an additional 12 months extended warranty service.

The New Elcometer Automotive Paint Meter The next generation automotive refinishing gauge for instant measurement of paint thickness. USB; to computer. Mean average ; x. Highest reading; Hi. Lowest reading; Lo. Nominal dry film thickness; NDFT. F, N, FNF. Factory; resets to the factory calibration. Zero offset 4 ; for calibration according to ISO V-Probe Adaptor Ideal for precision placement for the most accurate results on medium and large diameter curved surfaces such as pipes and cylinders.

Probe Placement Jig The Elcometer probe placement jig is the ideal accessory for measuring coatings on small or complex components when the highest levels of repeatability and accuracy are required.

SHRIMAD BHAGWAT KATHA PDF

Elcometer 456 Coating Thickness Gauge

The coating thickness gauge even informs the user when to replace the cap. As the probe is lifted off the surface the gauge displays the average coating thickness value, the highest thickness and the lowest dry film thickness values. Each set of three dry film readings average, high and low can be displayed on the run graph and stored into the coating thickness gauge's memory. During each scan, the Elcometer coating thickness gauge displays the live thickness reading together with an analogue bar graph which graphically indicates the thickness relative to both the nominal thickness and any user-defined limits. Each individual dry film thickness reading is stored into the memory. Working with Standards and Test Methods. The Elcometer Coating Thickness Gauge Model S or Model T can be set with a counted average of three and a fixed batch size of five to meet these requirements.

SOMEONE LIKE YOU NOVEL BY DURJOY DATTA PDF

What is a Coating Thickness Gauge?

Elcometer Coating Thickness Gauge. Elcometer Mechanical Coating Thickness Gauge. Calibration Foils. The non-destructive coating thickness measurements can be taken on either magnetic steel surfaces or non-magnetic metal surfaces such as stainless steel or aluminium. Digital coating thickness gauges are ideal to measure coating thickness on metallic substrates. Electromagnetic induction is used for non-magnetic coatings on ferrous substrates such as steel, whilst the eddy current principle is used for non-conductive coatings on non-ferrous metal substrates.

CHEESECAKE FACTORY SKINNYLICIOUS MENU PDF

Elcometer 456 IPC Dry Film Thickness Gauge

Digital The Elcometer range of digital coating thickness gauges has been specifically designed to provide highly accurate, reliable and repeatable coating thickness measurements on almost any substrate, whether ferrous or non-ferrous. Dry Film Thickness can be measured on either magnetic steel surfaces or non-magnetic metal surfaces such as stainless steel or aluminium using a digital coating thickness gauge. The principle of electromagnetic induction is used for non-magnetic coatings on magnetic substrates such as steel. The eddy current principle is used for non-conductive coatings on non-ferrous metals substrates. Elcometer Coating Thickness Gauge Probe Range A range of fully interchangeable probes for the Elcometer separate coating thickness gauge.

ASTM C303 PDF

Elcometer 456 Coating Thickness Gauge Probe Range

Pre-calibrated with 4 profile ranges to ensure accurate coating thickness measurement on blasted substrates, the Elcometer IPC Thickness Gauge is fast and very easy to use. The user selectable surface profiles include smooth, fine, medium and coarse ranges. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.

Related Articles